LAN CABLE
Communication Cable
LAN Cable Patch Cord
Power/Control Cable
Fiber Optic Pacth Cord
Fiber Cable
Introduction
Certification
Our Honor
Equipment
Industry News
Company News
HYA- Non-filling Local Cable
Product application:
It is mainly used for audio and video communication within the General Administration of Telecommunications and between exchanges and users. It is also used as an audio connection between other communication devices. It supports the connection of voice, digital phone and fax devices. It is the branch and main line of telecommunications cabling system.
Standards:
ANSI/ICEA S-84-608 ANSI/ICEA S-85-625 CSN IEC 708-1 YD/T 322
Product features:
·Compliant with YD/T 322 performance standards, suitable for outdoor voice backbone connections, with good mechanical and environmental performance;
·The insulated wire adopts standard chromatography, and the lay length of each pair is set ·reasonably, which is easy to distinguish and maintain during construction;
Conductor diameter(mm)
Pairs
Cable diameter(mm)
Cable Net(kg/km)
0.4
5
8.4±0.5
50.4
0.5
8.5±0.5
63.2
10
9±0.5
73.9
10.2±0.5
97.5
15
9.7±0.5
94.6
11±0.5
127.8
20
10.5±0.5
113.7
12.2±0.5
156.8
25
11.4±0.5
132.8
13.4±0.5
187.1
30
12.8±0.5
155.4
15±0.5
217.2
40
191.4
15.7±1.0
270.9
50
224
17.4±1.0
318.5
75
16.9±1.0
306.8
19.7±1.0
444.6
80
322.9
20.2±1.0
469.5
100
18.6±1.0
388.7
22.2±1.0
569.8
150
21.2±1.0
558
25.8±1.0
839
200
24.3±1.0
736
29.3±1.0
1087
250
26.8±1.0
793
32.3±2.0
1325
300
28.8±1.0
1055
34.8±2.0
1567
350
30.3±2.0
1209
36.8±2.0
1801
400
1364
39.9±2.0
2072
500
35.3±2.0
1668
43.4±2.0
2538
600
38.9±2.0
2011
47.3±2.0
3031
700
41.4±2.0
2313
50.8±3.0
3493
800
43.9±2.0
2613
53.8±3.0
3954
900
46.3±2.0
2943
57.2±3.0
4446
1000
48.3±3.0
3237
59.7±3.0
4901
1200
52.8±3.0
3834
64.7±3.0
5814
1400
56.7±3.0
4457
70.3±3.0
6780
1500
58.2±3.0
4756
71.8±3.0
7237
1600
60.2±3.0
4963
74.3±3.0
7690
1800
63.2±3.0
5645
2000
66.8±3.0
6296
2400
72.8±3.0
7476
0.6
0.7
10.2±1.0
101
12.4±1.0
131
12±1.0
158
13.7±1.0
209
15.2±1.0
263
283
17.7±1.0
367
18.7±1.0
429
566
23.8±1.0
666
27.3±1.0
873
812
29.8±1.0
1070
34.9±1.0
1544
39.9±1.0
2047
40.9±2.0
2230
47.8±2.0
46.8±2.0
53.8±2.0
3928
Electrical Characteristics
NO.
Item
Unit
Value
1
Conducter DC Resistance +20℃
Ω/km
Conductor diameter,mm
Maximum
148.0
95.0
65.8
36.6
2
DC Resistance Unbalance +20℃
%
Average ≤
1.5
5.0
4.0
3
Insulation resistance +20℃ DC100-500V
MΩ·km
Minimum 10×103
4
Dielectric Strength DC
KV
Applied voltage time
3s
1min
Conductor to Conductor
2.0
1.0
Conductor to Screen
6.0
3.0
Working capacitor 0.8kHz or 1kHz
nF/km
Cable pairs
﹥ 10
58.0
57.0
Average
52.0±4.0
52.0±2.0
6
Capacitance unbalance 0.8kHz or 1kHz
pF/km
Pair to Pair
Line with the ground capacitance unbalance
2630
----
570
7
Attenuation +20℃
dB/km
≥10Pairs cable:150kHz
12.1
9.0
7.2
5.7
1024kHz
27.3
22.5
18.5
13.7
8
Near End Crosstalk1024kHz
Length ≥0.3km
150KHz
dB
≥52
300KHz
≥48
1000KHz
≥40
9
ELFEXT at 1km
≥58
≥42
PSNEXT
≥49
≥45
≥37
11
PSELFEXT at 1km
≥54
≥38
Physical Characteristics
Insulation Color Transfer
NO Transfer
Treatment temperature
℃
80±2
Processing time
h
24
Tensile strength of insulation
Mpa
≥16
Insulation Elongation
≥300
Winding insulation temperature
Invalid/Test number
0/10
-55±1
Insulation heat shrink
≤5
115±2
Insulation resistance after heat aging properties of entangled
Thermal aging treatment temperature
Thermal aging treatment time
24×14
Aging temperature again
70±2
Sheath tensile strength
≥10
Sheath elongation
Thermal aging of the former
≥350
After thermal aging treatment
100±2
24×10
Sheath resistance to environmental stress cracking resistance
Soaking time
96
Jacket heat shrink